Smart HART-enabled temperature transmitter for RTD, thermocouple and mV inputs.
- ▪±0.1 °C accuracy
- ▪Dual input & hot backup
- ▪HART / PROFIBUS

Product Overview
The NX-TT300 is a universal, dual-input temperature transmitter accepting Pt100 / Pt1000 RTD, all common thermocouple types (J, K, T, N, S, R, B, E) and mV signals. It provides accurate, isolated 4–20 mA + HART output with sensor drift detection, redundancy and hot backup — ideal for critical loops in refineries, power plants and reactors.
Working Principle: The transmitter energises the RTD or reads the thermocouple mV signal, linearises it against the sensor's characteristic curve (per IEC 60751 / IEC 60584), applies cold-junction compensation for TC inputs, and outputs a temperature-linear 4–20 mA signal with digital HART overlay.
Technical Specifications
| Product Type | Smart Temperature Transmitter |
|---|---|
| Model Number | NX-TT300 |
| Input Type | RTD (2/3/4-wire), TC (J,K,T,N,S,R,B,E), mV, Ohm |
| Sensor Redundancy | Dual Input, Hot Backup, Drift Alarm |
| Measuring Range | -200 °C to +1,820 °C (sensor dependent) |
| Accuracy | ±0.1 °C (Pt100), ±0.2 % TC |
| Output Signal | 4–20 mA + HART 7, PROFIBUS PA, FF |
| Isolation | 500 V AC input/output/ground |
| Power Supply | 10–42 VDC |
| Ambient Temp. | -40 °C to +85 °C |
| Housing | DIN rail / Head-mount (Form B) / Field housing |
| Protection | IP20 (head), IP66/67 (field housing) |
| Ex Certification | ATEX, IECEx (Ex ia / Ex d) |
| Certification | SIL2, CE, RoHS, ISO 9001 |
Key Features
- ✓Dual Sensor Input
- ✓Sensor Drift Detection
- ✓Hot Backup Redundancy
- ✓Galvanic Isolation
- ✓High Accuracy
- ✓Rugged Industrial Construction
- ✓Corrosion Resistant Materials
- ✓Long Service Life
- ✓Low Maintenance
- ✓Easy Installation & Commissioning
- ✓High Repeatability
- ✓Digital Local Display
Applications
- ▸Reactor & Distillation Columns
- ▸Boiler & Furnace Skin Temperature
- ▸Bearing & Motor Monitoring
- ▸Tank & Vessel Temperature
- ▸Cold Chain & Pharma Storage
- ▸HVAC Chillers
Industries: Oil & Gas · Water Treatment · Chemical · Food Processing · Pharmaceuticals · Cement · Steel · Power Plants · HVAC · Textile
Model & Ordering Information
| Mounting | Head-mount (DIN Form B), DIN-rail, Field housing |
|---|---|
| Inputs | Single / Dual |
| Protocol | HART 7, PROFIBUS PA, FOUNDATION Fieldbus |
Certifications: ISO 9001, CE, RoHS, ATEX, IECEx, SIL2, IP66 / IP67, BIS